25 pin D-SUB MALE connector  at the DTE (Computer)
Pin Name Dir Description Circuit Paired with
1   --- Shield   18
2 TxD --> Transmitted Data BA 14
3 RxD <-- Received Data BB 16
4 RTS --> Request To Send CA 19
5 CTS <-- Clear To Send CB 13
6 DSR <-- Data Set Ready CC 22
7 SGND --- Signal Ground Ground 21
8 DCD <-- Data Carrier Detect CF 10
9   <-- Rtrn Receive Sig. Elmnt Timing DD 17
10   <-- Rtrn DCD CF 8
11   --> Rtrn Transmit Sig. Elmnt Timing DA 24
12   <-- Rtrn Transmit Sig. Elmnt Timing DB 15
13   <-- Rtrn CTS CB 5
14   --> Rtrn TxD BA 2
15   <-- Transmit Signal Element Timing DB 12
16   <-- Rtrn RxD BB 3
17   <-- Receive Signal Element Timing DD 9
18 LL --> Local Loopback LL 1
19   --> Rtrn RTS CA 4
20 DTR --> Data Terminal Ready CD 23
21 RL --> Remote Loopback RL 7
22   <-- Rtrn DSR CC 6
23   --> Rtrn DTR CD 20
24   --> Transmit Signal Element timing DA 11
25   <-- Test Mode TM  

25 pin D-SUB FEMALE connector  at the DCE (Modem)

Note: Direction is DTE (Computer) relative DCE (Modem)